This device transmits the control command of the GUI operation program to the slave unit using a wired RS-485 signal.

  • For wired communications, the master unit can monitor and control a maximum of 32 slave units.
  • For wireless communications, the master unit can monitor and control a maximum of 200 lighting fixtures.

Application

Industrial high bay, Sports Lighting, High mast, Flood Light

Certifications

UL, FCC

Specifications

Item

Description

Model Name

Master

Power Consumption

MAX. 2.5W

Communication Method

Wired (RS-485) / Wireless

Data Rate 

115,200[bps] / 250kbps 

Input Voltage

100 ~ 277Vac / 100 ~ 240Vac

Dimension

8.5 x 13.2 x 5.5 (inch)

216 x 336 x 140 (mm)

Weight

8.4 lb

3.8 kg

Operation Temp.

-20º ~ +60ºC / -4ºF ~ +140ºF